Trip current rating (AT) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
XT1 (3P) |
160A frame TMD 16A |
TMD 20A |
TMD 25A |
TMD 32A |
TMD 40A |
TMD 50A |
TMD 63A |
TMD 80A |
TMD 100A |
TMD 125A |
TMD 160A |
18kA (B) | |||||||||||
25kA (C) | - | - | |||||||||
36kA (N) | - | - | - | ||||||||
50kA (S) | - | - | - | - | - | ||||||
70kA (H) | - | - | - | - | - |
Trip current rating (AT) | |||||||
---|---|---|---|---|---|---|---|
XT3 (3P) |
250A frame TMD 63A |
TMD 80A |
TMD 100A |
TMD 125A |
TMD 160A |
TMD 200A |
TMD 250A |
36kA (N) | |||||||
50kA (S) |
Trip current rating (AT) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XT1 (4P) |
160A frame TMD 16A |
TMD 20A |
TMD 25A |
TMD 32A |
TMD 40A |
TMD 50A |
TMD 63A |
TMD 80A |
TMD 100A |
TMD 125A (Neutral 50% rating) |
TMD 125A (Neutral 100% rating) |
TMD 160A (Neutral 50% rating) |
TMD 160A (Neutral 100% rating) |
18kA (B) | |||||||||||||
25kA (C) | - | - | |||||||||||
36kA (N) | - | - | - | ||||||||||
50kA (S) | - | - | - | - | - | ||||||||
70kA (H) | - | - | - | - | - |
Trip current rating (AT) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
XT3 (4P) |
250A frame TMD 63A |
TMD 80A |
TMD 100A |
TMD 125A (Neutral 50% rating) |
TMD 125A (Neutral 100% rating) |
TMD 160A (Neutral 50% rating) |
TMD 160A (Neutral 100% rating) |
TMD 200A (Neutral 50% rating) |
TMD 200A (Neutral 100% rating) |
TMD 250A (Neutral 50% rating) |
TMD 250A (Neutral 100% rating) |
36kA (N) | |||||||||||
50kA (S) |
for XT1 3P (plug-in) |
for XT2 3P (plug-in) |
for XT2 3P (withdrawable) |
for XT3 3P (plug-in) |
for XT4 3P (plug-in) |
for XT4 3P (withdrawable) |
for XT1 4P (plug-in) |
for XT2 4P (plug-in) |
for XT2 4P (withdrawable) |
for XT3 4P (plug-in) |
for XT4 4P (plug-in) |
for XT4 4P (withdrawable) ![]() |
|
Front connecting |
||||||||||||
Rear connecting |
Compatible with |
XT1 (fixed&plug-in) |
XT2 (fixed&plug-in) |
XT2 (withdrawable) |
XT3 (fixed&plug-in) |
XT4 (fixed&plug-in) |
XT4 (withdrawable) |
Shunt opening release ![]() |
||||||
Undervoltage release ![]() |
||||||
Delay device for undervoltage release ![]() |
![]() Compatible with |
XT1 (fixed&plug-in) |
XT2 (fixed&plug-in) |
XT2 (withdrawable) |
XT3 (fixed&plug-in) |
XT4 (fixed&plug-in) |
XT4 (withdrawable) |
1 C/O + 1 trip (24Vdc) |
||||||
1 C/O + 1 trip (250Vac) |
||||||
2 C/O + 1 trip (250Vac) |
- | - | ||||
3 C/O Left (250Vac) |
- | - | ||||
3 C/O + 1 trip (250Vac) |
- |
Compatible with |
Motor operator (220V 50Hz) ![]() |
Rotary handle (direct) ![]() |
Rotary handle (transmitted) ![]() |
Fixed padlock ![]() |
Terminal covers Low (3P) ![]() |
Terminal covers High (3P) ![]() |
Terminal covers Low (4P) ![]() |
Terminal covers High (4P) ![]() |
XT1 | ||||||||
XT2 | ||||||||
XT3 | ||||||||
XT4 |